1. The altitude does not exceed 1000m;
2. Ambient air temperature: upper limit +40 ° C, lower limit -25 ° C;
3. Relative humidity of the surrounding environment: the daily average is not more than 95%, and the monthly average is not more than 90%;
4. The seismic intensity does not exceed 8 degrees;
5. Installation location: no fire, flammable, explosive, serious pollution, chemical corrosion and severe vibration.
Model Rated voltage
(KV)Rated voltage
(V)4 seconds steady current Dynamic steady current GN19-10(C)400-12.5 12 400 12.5 31.5 GN19-10(C)630-20 630 20 50 GN19-10(C)1000-31.5 1000 31.5 80 GN19-10(C)1250-40 1250 40 100
The Eberry GN19 11KV 12KV Disconnect Switch Isolating Switch 12KV VCB is a high-voltage switching device designed for industrial substations, utility networks, and indoor/outdoor power distribution applications. This switch offers reliable circuit isolation, vacuum circuit breaker (VCB) protection, and durable construction, ensuring safety, operational efficiency, and low maintenance.
This guide provides detailed instructions on operation, maintenance, storage, and precautions, enabling engineers, operators, and procurement professionals to maximize device performance and longevity.
Product Overview
Key Features and Advantages
Technical Specifications
Operation Guidelines
Safety Precautions and Notices
Maintenance Requirements
Storage and Environmental Conditions
Troubleshooting and Common Issues
Applications and Use Cases
After-Sales Support
Conclusion
The GN19 Disconnect Switch is suitable for medium-voltage networks with rated voltages of 11KV and 12KV. It features VCB technology for vacuum arc interruption, ensuring safe switching under load conditions.
Disconnect Function: Isolates circuits for maintenance or fault handling.
VCB Integration: Provides high arc-quenching capability.
Indoor/Outdoor Design: Suitable for diverse installation environments.
Durable Construction: Ensures long operational life.
Feature | Advantage |
---|---|
Rated Voltage 11KV / 12KV | Medium-voltage applications |
Vacuum Circuit Breaker (VCB) | Arc-free and reliable switching |
Disconnect/Isolating Function | Safe isolation of circuits |
Indoor/Outdoor Installation | Flexible deployment |
Low Maintenance Requirement | Reduced downtime and operational costs |
IEC and International Standards | Global compliance |
Compact Design | Space-saving and easy integration |
Handcart or Fixed Options | Flexible operation and maintenance |
Parameter | Specification |
---|---|
Rated Voltage | 11KV / 12KV |
Rated Current | Up to 1250A |
Short-Circuit Breaking Capacity | 25kA |
Insulation Level | IEC 62271 Standard |
Operating Mechanism | Manual or spring-assisted |
Handcart / Fixed Type | Optional depending on application |
Ambient Temperature | -10°C to +40°C |
Relative Humidity | ≤95% |
Protection Grade | IP20/IP30 |
Before operating the GN19 VCB disconnect switch, ensure:
All personnel are trained and authorized.
Protective equipment (PPE) is worn.
The installation site is free of debris and moisture.
Circuit diagrams and labels are verified.
Grounding is properly connected.
Verify OFF Position: Ensure the switch is open before any maintenance.
Control Panel Operation: Use manual or motor-assisted controls to operate the VCB.
Load Switching: Confirm rated load before closing.
Circuit Isolation: Engage disconnect function to isolate circuits safely.
Monitoring: Check indicators and alarms during operation.
Step | Status/Notes |
---|---|
Switch Position | Verified OFF for maintenance |
Control Panel | Checked for functionality |
Load Verification | Confirmed within rated parameters |
Isolation Engagement | Successfully isolated |
Indicators & Alarms | Monitored for correct status |
Safety is paramount when handling high-voltage disconnect switches. Follow these guidelines:
Do not operate with wet hands or in wet conditions.
Always wear PPE: insulated gloves, helmets, boots.
Confirm grounding before touching any components.
Do not bypass interlocks or safety mechanisms.
Keep a safe distance from energized circuits.
Conduct periodic safety audits and inspection.
Proper maintenance ensures long operational life and prevents failures.
Task | Frequency | Description |
---|---|---|
Visual Inspection | Monthly | Check for dust, corrosion, and damage |
Mechanical Operation Test | Quarterly | Ensure smooth VCB operation |
Contact Surface Cleaning | Bi-Annually | Remove oxidation or debris |
Lubrication of Moving Parts | Bi-Annually | Prevent mechanical wear |
Insulation Resistance Test | Annually | Verify dielectric strength |
Issue | Possible Cause | Recommended Action |
---|---|---|
Switch fails to operate | Misalignment or mechanical blockage | Adjust alignment and lubricate |
Failure to trip | Faulty control circuit | Repair or replace control unit |
Abnormal noise during operation | Worn moving parts | Lubricate or replace components |
Loose connections | Thermal expansion or vibration | Tighten electrical connections |
Unexpected trip | Incorrect wiring or load | Check wiring and load parameters |
Proper storage preserves the functional integrity of the GN19 VCB disconnect switch.
Store in a dry, ventilated indoor area.
Avoid direct sunlight and moisture exposure.
Maintain temperature range: -10°C to +40°C.
Keep dust-free and away from corrosive gases.
Inspect stored units periodically for signs of deterioration.
Ensure storage area has stable humidity ≤95%.
Avoid mechanical shocks during transportation or handling.
Store on level surfaces to prevent deformation.
Handcart misalignment: Adjust rails and guides.
Stiff operation: Lubricate moving parts and check for obstructions.
Failure to close/open: Inspect control wiring and auxiliary contacts.
Insulation degradation: Conduct insulation resistance tests and replace components if necessary.
Trip under normal load: Verify load current, control circuit settings, and proper installation.
Indicator failure: Check bulbs, sensors, and wiring.
Industrial Substations: Reliable medium-voltage isolation.
Utility Networks: Protects 11KV/12KV circuits efficiently.
Commercial Buildings: Ensures safe and uninterrupted power supply.
Renewable Energy Facilities: Integrates with solar and wind distribution systems.
Indoor and Outdoor Deployments: Suitable for diverse installation conditions.
Service Type | Description |
---|---|
Technical Consultation | Guidance on installation and operation |
Spare Parts Supply | OEM parts for replacements |
On-Site Commissioning | Setup and functional testing |
Preventive Maintenance | Scheduled inspections and servicing |
Remote Assistance | Online troubleshooting support |
Reliable after-sales service ensures minimal downtime and long-term operational safety.
The Eberry GN19 Factory High Voltage 11KV/12KV Disconnect Switch Isolating Switch 12KV VCB provides safe, reliable, and IEC-compliant high-voltage switching. With handcart or fixed installation, vacuum interruption, low maintenance, and versatile deployment, it is ideal for industrial, utility, and indoor/outdoor substations. Following proper operation, safety, maintenance, and storage protocols ensures long-term reliability and optimal performance.
Phone: +8613736779975
E-mail: sales@vcbbreaker.com
Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China
Copyright © 2025 Yangmei Electric Group All rights reserved
This website uses cookies to ensure you get the best experience on our website.