    The Eberry GN19 11KV 12KV Disconnect Switch Isolating Switch 12KV VCB offers reliable high-voltage circuit isolation and protection. Designed for industrial and utility applications, it ensures safe switching, low maintenance, and compliance with IEC standards, providing durable performance for substations, distribution networks, and indoor/outdoor high-voltage installations.
  • Share:
  • Contact us Inquiry
  • WhatsApp:8613736779975

Environmental conditions:

1. The altitude does not exceed 1000m;

2. Ambient air temperature: upper limit +40 ° C, lower limit -25 ° C;

3. Relative humidity of the surrounding environment: the daily average is not more than 95%, and the monthly average is not more than 90%;

4. The seismic intensity does not exceed 8 degrees;

5. Installation location: no fire, flammable, explosive, serious pollution, chemical corrosion and severe vibration.

The main technical parameters:

ModelRated voltage
(KV)
Rated voltage
(V)
4 seconds steady currentDynamic steady current
GN19-10(C)400-12.512 40012.531.5
GN19-10(C)630-206302050
GN19-10(C)1000-31.5100031.580
GN19-10(C)1250-40125040100


The Eberry GN19 11KV 12KV Disconnect Switch Isolating Switch 12KV VCB is a high-voltage switching device designed for industrial substations, utility networks, and indoor/outdoor power distribution applications. This switch offers reliable circuit isolation, vacuum circuit breaker (VCB) protection, and durable construction, ensuring safety, operational efficiency, and low maintenance.


This guide provides detailed instructions on operation, maintenance, storage, and precautions, enabling engineers, operators, and procurement professionals to maximize device performance and longevity.


Table of Contents

  1. Product Overview

  2. Key Features and Advantages

  3. Technical Specifications

  4. Operation Guidelines

  5. Safety Precautions and Notices

  6. Maintenance Requirements

  7. Storage and Environmental Conditions

  8. Troubleshooting and Common Issues

  9. Applications and Use Cases

  10. After-Sales Support

  11. Conclusion


1. Product Overview

The GN19 Disconnect Switch is suitable for medium-voltage networks with rated voltages of 11KV and 12KV. It features VCB technology for vacuum arc interruption, ensuring safe switching under load conditions.

  • Disconnect Function: Isolates circuits for maintenance or fault handling.

  • VCB Integration: Provides high arc-quenching capability.

  • Indoor/Outdoor Design: Suitable for diverse installation environments.

  • Durable Construction: Ensures long operational life.


2. Key Features and Advantages

FeatureAdvantage
Rated Voltage 11KV / 12KVMedium-voltage applications
Vacuum Circuit Breaker (VCB)Arc-free and reliable switching
Disconnect/Isolating FunctionSafe isolation of circuits
Indoor/Outdoor InstallationFlexible deployment
Low Maintenance RequirementReduced downtime and operational costs
IEC and International StandardsGlobal compliance
Compact DesignSpace-saving and easy integration
Handcart or Fixed OptionsFlexible operation and maintenance

3. Technical Specifications

ParameterSpecification
Rated Voltage11KV / 12KV
Rated CurrentUp to 1250A
Short-Circuit Breaking Capacity25kA
Insulation LevelIEC 62271 Standard
Operating MechanismManual or spring-assisted
Handcart / Fixed TypeOptional depending on application
Ambient Temperature-10°C to +40°C
Relative Humidity≤95%
Protection GradeIP20/IP30

4. Operation Guidelines

4.1 Pre-Operation Checklist

Before operating the GN19 VCB disconnect switch, ensure:

  • All personnel are trained and authorized.

  • Protective equipment (PPE) is worn.

  • The installation site is free of debris and moisture.

  • Circuit diagrams and labels are verified.

  • Grounding is properly connected.

4.2 Operation Procedure

  1. Verify OFF Position: Ensure the switch is open before any maintenance.

  2. Control Panel Operation: Use manual or motor-assisted controls to operate the VCB.

  3. Load Switching: Confirm rated load before closing.

  4. Circuit Isolation: Engage disconnect function to isolate circuits safely.

  5. Monitoring: Check indicators and alarms during operation.

4.3 Operational Checklist

StepStatus/Notes
Switch PositionVerified OFF for maintenance
Control PanelChecked for functionality
Load VerificationConfirmed within rated parameters
Isolation EngagementSuccessfully isolated
Indicators & AlarmsMonitored for correct status

5. Safety Precautions and Notices

Safety is paramount when handling high-voltage disconnect switches. Follow these guidelines:

  • Do not operate with wet hands or in wet conditions.

  • Always wear PPE: insulated gloves, helmets, boots.

  • Confirm grounding before touching any components.

  • Do not bypass interlocks or safety mechanisms.

  • Keep a safe distance from energized circuits.

  • Conduct periodic safety audits and inspection.

Indoor High voltage Handcart Type Vacuum Circuit Breaker



6. Maintenance Requirements

Proper maintenance ensures long operational life and prevents failures.

6.1 Routine Maintenance

TaskFrequencyDescription
Visual InspectionMonthlyCheck for dust, corrosion, and damage
Mechanical Operation TestQuarterlyEnsure smooth VCB operation
Contact Surface CleaningBi-AnnuallyRemove oxidation or debris
Lubrication of Moving PartsBi-AnnuallyPrevent mechanical wear
Insulation Resistance TestAnnuallyVerify dielectric strength

6.2 Troubleshooting Common Issues

IssuePossible CauseRecommended Action
Switch fails to operateMisalignment or mechanical blockageAdjust alignment and lubricate
Failure to tripFaulty control circuitRepair or replace control unit
Abnormal noise during operationWorn moving partsLubricate or replace components
Loose connectionsThermal expansion or vibrationTighten electrical connections
Unexpected tripIncorrect wiring or loadCheck wiring and load parameters

7. Storage and Environmental Conditions

Proper storage preserves the functional integrity of the GN19 VCB disconnect switch.

7.1 Storage Guidelines

  • Store in a dry, ventilated indoor area.

  • Avoid direct sunlight and moisture exposure.

  • Maintain temperature range: -10°C to +40°C.

  • Keep dust-free and away from corrosive gases.

  • Inspect stored units periodically for signs of deterioration.

7.2 Environmental Considerations

  • Ensure storage area has stable humidity ≤95%.

  • Avoid mechanical shocks during transportation or handling.

  • Store on level surfaces to prevent deformation.


8. Troubleshooting and Common Issues

8.1 Mechanical Problems

  • Handcart misalignment: Adjust rails and guides.

  • Stiff operation: Lubricate moving parts and check for obstructions.

8.2 Electrical Problems

  • Failure to close/open: Inspect control wiring and auxiliary contacts.

  • Insulation degradation: Conduct insulation resistance tests and replace components if necessary.

8.3 Operational Failures

  • Trip under normal load: Verify load current, control circuit settings, and proper installation.

  • Indicator failure: Check bulbs, sensors, and wiring.


9. Applications and Use Cases

  • Industrial Substations: Reliable medium-voltage isolation.

  • Utility Networks: Protects 11KV/12KV circuits efficiently.

  • Commercial Buildings: Ensures safe and uninterrupted power supply.

  • Renewable Energy Facilities: Integrates with solar and wind distribution systems.

  • Indoor and Outdoor Deployments: Suitable for diverse installation conditions.


10. After-Sales Support

Service TypeDescription
Technical ConsultationGuidance on installation and operation
Spare Parts SupplyOEM parts for replacements
On-Site CommissioningSetup and functional testing
Preventive MaintenanceScheduled inspections and servicing
Remote AssistanceOnline troubleshooting support

Reliable after-sales service ensures minimal downtime and long-term operational safety.



The Eberry GN19 Factory High Voltage 11KV/12KV Disconnect Switch Isolating Switch 12KV VCB provides safe, reliable, and IEC-compliant high-voltage switching. With handcart or fixed installation, vacuum interruption, low maintenance, and versatile deployment, it is ideal for industrial, utility, and indoor/outdoor substations. Following proper operation, safety, maintenance, and storage protocols ensures long-term reliability and optimal performance.



ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!
Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Copyright ©  2025 Yangmei Electric Group  All rights reserved

Sitemap

This website uses cookies to ensure you get the best experience on our website.

Accept Reject