  • LW16-40.5 Outdoor SF6 Circuit Breaker High Voltage Reliable Durable Power Transmission Equipment for Substation Electrical Protection

LW16-40.5 Outdoor SF6 Circuit Breaker High Voltage Reliable Durable Power Transmission Equipment for Substation Electrical Protection

The LW16-40.5 outdoor SF6 circuit breaker is designed for use in a 50 Hz three-phase AC power system and is suitable for control and protection in industrial enterprises, power plants, and substations. This product is capable of frequent operations and can be used as a link circuit breaker and for switching capacitor banks or reactor banks.

Share to:

Product Introduction

The LW16-40.5 outdoor SF6 circuit breaker is designed for use in a 50 Hz three-phase AC power system and is suitable for control and protection in industrial enterprises, power plants, and substations. This product is capable of frequent operations and can be used as a link circuit breaker and for switching capacitor banks or reactor banks. The internal current transformers can be used for measurement and protection. It can directly replace the SW2-35 oil circuit breaker and, with the addition of an overcurrent bracket, can replace various models of oil circuit breakers. It is an ideal oil-free circuit breaker for 35 kV power systems.

Note: When the circuit breaker is in hot standby mode, surge arresters must be installed on the fault side of the breaker.

Main Technical Parameters of Circuit Breaker

No.Parameter NameUnitParameter Value
1Rated voltagekV40.5
21-Minute power frequency withstand voltagekV95 (Grounded) / 185 (Contact gap)
3Rated frequencyHz50
4Rated currentA1600, 2000
5Rated short-circuit breaking currentkA25 (reclosing), 31.5 (single separation)
6Rated short-circuit making current (peak)kA63
7Rated short-time withstand currentkA25
8Rated short circuit durations4
9Rated peak withstand currentkA63
10Rated operating sequenceO—0.3s—CO—180s—CO
11Rated switching current for a single capacitor bankA400
12Rated out-of-step breaking currentkA6.3
13Rated out-of-phase breaking currentkA21.75
14Mechanical life testTimes3000
15Rated cumulative breaking times (rated current)Times2000
16Rated cumulative breaking times (25kA short-circuit)Times21
17Tripping times≤0.06 (rated/max voltage) / ≤0.10 (min voltage)
18Closing times≤0.15
19SF6 gas rated pressure (20℃ gauge pressure)MPa0.60±0.015
20SF6 gas refill alarm pressure (20℃ gauge pressure)MPa0.55±0.015
21SF6 gas minimum functional pressure (20℃ gauge)MPa0.52±0.015
22SF6 gas annual leakage rate%/Year≤1
23SF6 gas trace moisture contentppm (V/V)≤150×10⁻⁶
24CT14-A mechanism coil rated voltageVDC: 110/220; AC: 220/380
25SF6 gas weightkgNormal: 2.5; CT: 6; Elevated CT: 8
26Circuit breaker weightkg1000
27External insulation leakage specific distancemm/kV≥31
28Porcelain insulator leakage distancemm≥1255

Notes:

O: Open operation 

CO: Close-Open operation 

s: Seconds 

ppm: Parts per million 

CT: Current Transformer configuration 

Formatting Consistency:

  • Values with tolerances (e.g., ±0.015) and conditional parameters (e.g., reclosing/single separation) are explicitly stated.   
  • Units standardized (e.g., “kV” for kilovolts, “MPa” for megapascals).   
  • Scientific notation corrected (e.g., “≤150×10⁻⁶” instead of “X10-6”).   
  • Combined entries (e.g., tripping time under different voltages) are merged for clarity.