  • LW36-145 Outdoor SF6 Circuit Breaker High Voltage 40.5kV Automatic Power Distribution Equipment For Substation Electrical Protection

LW36-145 Outdoor SF6 Circuit Breaker High Voltage 40.5kV Automatic Power Distribution Equipment For Substation Electrical Protection

The LW36-145/3150-40 self-powered SF6 circuit breaker is an outdoor type product, it is designed to disconnect rated current, fault current, or switch lines, achieving control and protection of the power system. It can also be used as a link circuit breaker.

Share to:

Product Introduction

The LW36-145/3150-40 self-powered SF6 circuit breaker is an outdoor type product, suitable for use in power grids with a maximum voltage of 145 kV, operating at 50 Hz and altitudes not exceeding 3000 meters, with an ambient temperature no lower than -40°C, and environmental pollution levels not exceeding level IV.

 It is designed to disconnect rated current, fault current, or switch lines, achieving control and protection of the power system. It can also be used as a link circuit breaker.

This product uses SF6 gas as the arc-extinguishing and insulating medium, and incorporates the most advanced self-powered arc-extinguishing technology. It is equipped with a new type of spring operating mechanism, offering features such as long electrical life, low operating force, low noise, and high reliability.

 Its simple structure, compact size, and long maintenance intervals make it an ideal choice for high-altitude regions or 132 kV power systems. It can replace similar imported products.

Structural Features

The circuit breaker adopts a three-phase porcelain column-type single-break structure, with a single spring operating mechanism shared by the three phases. It is centrally arranged with three-phase interlocking, giving it an innovative and refined appearance.

The circuit breaker uses SF6 gas as both the insulating and arc-extinguishing medium. During operation, the three poles of the breaker are connected via SF6 gas, and a pointer-type density relay is used to monitor its pressure and density progress. Due to the use of self-powered arc-extinguishing technology and optimized design in the breaker’s motion system, the mechanical efficiency is effectively improved, minimizing the operating force. The breaking performance is excellent, and the electrical life is long.

The installation base and support frame are made of high-quality steel plates, formed by overall bending. The surface is treated with hot-dip galvanizing, and all exposed fasteners are made from high-strength materials, either hot-dip galvanized or made of stainless steel. The mechanism box casing is made of stainless steel, ensuring excellent corrosion resistance, high mechanical reliability, and the ability to withstand frequent operations.

Main Technical Parameters of Circuit Breaker

No.Parameter NameUnitValue
1Rated voltagekVLW36-126KV
2Insulation levelkVSee Table 2
3Rated frequencyHz50
4Rated currentA3150
5Rated short-circuit breaking currentkA40
6Rated short-time withstand currentkA40
7Rated peak withstand currentkA100
8Rated short-circuit durations3
9Rated short-circuit making current (peak)kA100
10Near-zone fault breaking currentkA36/30
11Rated line charging breaking currentA31.5
12Rated out-of-step breaking currentkA10
13Cumulative short-circuit breaking operationstimes20
14First pole-to-clear factor1.5
15SF6 gas pressure (20°C)MPa0.5
16Rated voltage of control/auxiliary circuitsDC220V / DC110V*
17Rated operating sequenceO-0.3s-CO-180s-CO
18Mechanical characteristicsμΩSee Table 5
19Rated main circuit resistanceμΩ≤55
20Mechanical endurancetimes10000
21Terminal static pull forceNHorizontal longitudinal:1250
Horizontal lateral:  750
Vertical direction: 1000
22SF6 gas annual leakage rate%≤1
23SF6 gas moisture content (V/V)ppm≤150±4
24Contact travelmm150±4
25Contact closing travelmm25+3