Send Message
Home > products > Gas Insulated Switchgear GIS >
GIS Ring Main Unit 24kV 12kV Gas Insulated Switchboard Electrical Switchgear

GIS Ring Main Unit 24kV 12kV Gas Insulated Switchboard Electrical Switchgear

12kV Gas Insulated Switchboard

24kV Gas Insulated Switchboard

Electrical Switchgear Gas Insulated Switchboard

Place of Origin:

China

Brand Name:

Eberry

Model Number:

SF6 Insulated Switchgear

Contact Us

Request A Quote
Product Details
Insulation Gas:
SF6
Mechanical Life:
10000 Time
Three-position Switch:
5000 Time
Rated Frequency:
50 Hz
Payment & Shipping Terms
Minimum Order Quantity
1 set
Packaging Details
Plywood carton
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
10000pcs/month
Product Description

Our Catalogue

 

Eberry switchgear catalogue in Russian.pdf

Eberry switchgear catalogue.pdf

EBERRY VCB CATALOGUE.PDF

 

Product Descriprtion

 

The SF6 ring main unit (RMU) uses an SF6 load switch as the main switch. This compact and expandable metal-enclosed switchgear is suitable for distribution automation. It features a simple structure, flexible operation, reliable interlocking, and easy installation, providing satisfactory technical solutions for various applications and users. With the adoption of sensor technology and up-to-date protection relays, combined with advanced technology and flexible assembly options, the HXGN15 unit-type SF6 RMU can fully meet the requirements of a continuously evolving market.

The unit can be equipped with the self-produced FLBS36 SF6 load break switch. Additionally, based on user requirements, it can be assembled with internationally top-ranking VB4 series vacuum circuit breakers with permanent magnetic mechanisms made by AREVA, or HD4 type SF6 circuit breakers made by ABB, or our VS1.12 type vacuum circuit breakers with permanent magnetic mechanisms. The operation methods for the main switch inside the RMU can be either manual or electric power-driven. 

 

Product Paramenters

 

Item Unit Parameter
Rated voltage kV 12 24 40.5
Rated frequency Hz 50
Rated current A 630/1250/2500/3150/4000/630/1250/2500
Power frequency withstand voltage (phase-to-phase and phase-to-ground) kV 42 65 95
Power frequency withstand voltage (insulation breaking) kV 48 79 118
Lightning impulse withstand voltage (phase-to-phase and phase-to-ground) kV 75 125 185
Lightning impulse withstand voltage (insulation breaking) kV 85 145 215
Rated power frequency withstand voltage of auxiliary circuit kV 2
Rated instantaneous withstand current kA 25/31.5/40
Rated short-circuit period s 3
Rated peak withstand current kA 63/80/100 63/80/100 50/63/80
Rated short-circuit breaking current of circuit breaker kA 25/31.5/40 25/31.5/40 25/31.5
Rated short-circuit closing current of circuit breaker (peak) kA 63/80/100 63/80/100 50/63/80
Rated cable charge breaking current A 25
Rated operating sequence   O-0.3s-CO-3min-CO
Insulation gas   SF6
Mechanical life Time 10000
Three-position switch Time 5000
Rated charge pressure (abs, 20°C) Mpa 0.14
Minimum charge pressure (abs, 20°C) Mpa 0.12
Sealed enclosure Grade IP67
Switch shell Grade UP4X
Annual relative leak rate of dry air %/year ≤0.1
Rated power voltage of auxiliary circuit V DC48/110/220 AC220
     

 

 

GIS Ring Main Unit 24kV 12kV Gas Insulated Switchboard Electrical Switchgear 0GIS Ring Main Unit 24kV 12kV Gas Insulated Switchboard Electrical Switchgear 1GIS Ring Main Unit 24kV 12kV Gas Insulated Switchboard Electrical Switchgear 2

Send your inquiry directly to us

Privacy Policy China Good Quality Indoor Vacuum Circuit Breaker Supplier. Copyright © 2023-2024 vcbbreaker.com . All Rights Reserved.