Login | Register
Product
Product

Products

Home > Products > Switchgear Fittings > Copper Parts Contact Series > Contact Arm > 2000A Arc Resistant Contact Arm for VS1 VCB Vacuum Circuit Breaker High Durability and Reliability

2000A Arc Resistant Contact Arm for VS1 VCB Vacuum Circuit Breaker High Durability and Reliability

    2000A Arc Resistant Contact Arm for VS1 VCB Vacuum Circuit Breaker High Durability and Reliability

    The 2000A Arc Resistant Contact Arm for VS1 VCB Vacuum Circuit Breaker High Durability and Reliability is engineered for stable performance under demanding conditions. With exceptional arc resistance, long service life, and reliable conductivity, it ensures safe, efficient operation in medium-voltage switchgear for industrial, utility, and infrastructure applications.
  • Share:
  • Contact us Inquiry
  • WhatsApp:8613736779975

Dimensional drawing


Arc Resistant Contact Arm


The 2000A Arc Resistant contact arm for VS1 VCB vacuum circuit breaker High Durability and Reliability is a crucial component in medium-voltage electrical switchgear. Designed to withstand intense electrical arcs, high mechanical stress, and long-term operational wear, it ensures safe, stable, and reliable power transmission.


This article covers key aspects of this product, including usage precautions, solutions for common challenges, storage conditions, inspection, and maintenance practices. Written with SEO best practices, the content is structured for professional audiences such as power utilities, industrial engineers, procurement specialists, and global distributors.


Product Overview

  • Rated Current: 2000A

  • Application: VS1 VCB (Vacuum Circuit Breaker)

  • Core Features: Arc resistance, long durability, high reliability

  • Materials: High-conductivity copper alloy, silver/tin plated surface

  • Design Goal: To maintain low contact resistance, withstand arc erosion, and support high mechanical endurance

The contact arm plays a vital role in connecting fixed and moving contacts inside the VCB, ensuring uninterrupted current flow while withstanding arc discharges during switching operations.


Key Features

  1. Arc Resistant Design → Minimizes erosion and guarantees extended contact life.

  2. High Current Endurance → Rated for continuous 2000A current under demanding conditions.

  3. Mechanical Strength → Supports frequent switching operations without deformation.

  4. High Reliability → Low resistance and stable performance enhance safety.

  5. Compatibility → Tailored for VS1 VCB models, widely used in global switchgear systems.

  6. Durability → Engineered to deliver consistent performance over years of operation.


Usage Precautions

Correct installation and operation are critical to ensure the reliability of the 2000A Arc Resistant Contact Arm for VS1 VCB.

General Safety Precautions

  • Always de-energize equipment before inspection or replacement.

  • Use insulated tools to prevent electrical shock.

  • Verify proper alignment of the contact arm with mating components.

  • Avoid excessive force during installation to prevent mechanical deformation.

Operational Precautions

  • Do not exceed the 2000A rated current for continuous operation.

  • Minimize unnecessary frequent switching under load conditions to reduce arc stress.

  • Ensure that contact pressure is within specified limits to avoid overheating.

  • Maintain an environment with controlled humidity to prevent corrosion and oxidation.


Common Problems and Solutions

ProblemPossible CauseRecommended Solution
Excessive heatingHigh contact resistance due to oxidationClean and polish surface; re-tighten connections
Arc erosionFrequent switching under high loadReplace worn arms; reduce load switching frequency
Mechanical wearRepeated mechanical stress and vibrationPeriodic inspection and timely replacement
Loose contactMisalignment or insufficient contact pressureAdjust alignment and restore proper spring pressure
Surface oxidationExposure to moisture or corrosive atmosphereClean oxidation layer; apply protective coating

Storage Conditions

Proper storage extends the shelf life and reliability of contact arms before installation.


Arc Resistant Contact Arm


Environmental Requirements

  • Temperature: Store between -10°C and +40°C

  • Humidity: Below 75% relative humidity

  • Atmosphere: Free from corrosive gases, dust, and conductive particles

  • Light Exposure: Avoid direct sunlight and ultraviolet exposure

Packaging Requirements

  • Keep in sealed, anti-moisture packaging.

  • Use foam or anti-static material to prevent physical damage.

  • Clearly mark packaging with handling and safety instructions.


inspection and maintenance

Regular inspection and preventive maintenance ensure the long-term performance of the contact arm.

Inspection Checklist

  1. Visual Examination → Look for pitting, discoloration, or deformation.

  2. Surface Condition → Inspect for oxidation or corrosion.

  3. Contact Resistance Test → Measure resistance; values beyond limits indicate wear.

  4. Alignment Check → Ensure proper positioning and pressure.

Maintenance Guidelines

  • Routine Cleaning: Remove dust and debris using a lint-free cloth.

  • Lubrication: Apply conductive grease as recommended.

  • Tightening: Check mechanical fasteners to avoid loose connections.

  • Replacement Schedule: Replace arms showing signs of severe arc erosion or wear.

Preventive Maintenance Schedule

IntervalActivity
Every 3 monthsVisual inspection and surface cleaning
Every 6 monthsContact resistance testing
AnnuallyFull functional and alignment check
Every 5 yearsComprehensive overhaul and replacement review

Customer Applications

Power Utilities

Ensure stable grid operations with reduced downtime.

Industrial Facilities

Maintain reliable performance in steel plants, petrochemical complexes, and mining industries.

Renewable Energy Systems

Support solar and wind farms where frequent switching is required.

Infrastructure Projects

Ensure safe and uninterrupted power in transportation, airports, and large commercial centers.


Customer Feedback

  • Utility Company: “The 2000A Arc Resistant Contact Arm for VS1 VCB delivers consistent performance in our substations with minimal failures.”

  • Industrial Plant: “Durability under heavy load conditions is excellent. Maintenance intervals have been reduced significantly.”

  • Contractor: “Installation was straightforward, and the reliability exceeded expectations.”


Advantages for Buyers

  • Reduced Downtime → Lower risk of unexpected failures.

  • Cost Efficiency → Long-lasting design reduces replacement frequency.

  • Enhanced Safety → Reliable operation prevents overheating and arc flash risks.

  • Global Standards → Compliance with IEC and GB ensures international acceptance.

  • Wide Compatibility → Optimized for VS1 VCB systems used worldwide.



The 2000A Arc Resistant Contact Arm for VS1 VCB Vacuum Circuit Breaker High Durability and Reliability is engineered to deliver superior performance in demanding environments. With excellent resistance to arc erosion, reliable conductivity, and long service life, it supports the safe and efficient operation of modern electrical systems.


By following proper usage precautions, implementing solutions to common issues, ensuring correct storage, and carrying out scheduled inspections and maintenance, operators can maximize the lifespan and effectiveness of this critical component.


This makes the 2000A arc resistant contact arm an ideal choice for industries, utilities, and infrastructure projects seeking safety, reliability, and durability in their switchgear systems.



ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!
Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Copyright ©  2025 Yangmei Electric Group  All rights reserved

Sitemap

This website uses cookies to ensure you get the best experience on our website.

Accept Reject