Home > Products > Switchgear Fittings > Copper Parts Contact Series > Contact Arm > 2000A High Voltage Contact Arm for VCB Vacuum Circuit Breaker Resistant to Wear and Arc

2000A High Voltage Contact Arm for VCB Vacuum Circuit Breaker Resistant to Wear and Arc

    2000A High Voltage Contact Arm for VCB Vacuum Circuit Breaker Resistant to Wear and Arc

    The 2000A High Voltage Contact Arm for VCB Vacuum Circuit Breaker Resistant to Wear and Arc ensures reliable electrical performance with long-lasting durability. Designed to withstand high current, arc stress, and mechanical wear, it delivers stable operation, enhanced safety, and extended service life for demanding power distribution applications.
  • Share:
  • Contact us Inquiry
  • WhatsApp:8613736779975

Dimensional drawing


High Voltage Contact Arm


The 2000A High Voltage contact arm for VCB vacuum circuit breaker Resistant to Wear and Arc is an essential component in modern medium and high-voltage electrical systems. Its primary role is to ensure stable current transmission while withstanding extreme operational conditions such as high currents, frequent switching, and arc stress. With durability against wear and arc erosion, this contact arm guarantees Safe Operation and long service life for critical power distribution equipment.


This article provides a comprehensive overview of the product, including its applicable scope, fault diagnosis and repair, maintenance guidelines, and customer feedback. It is written to meet Google SEO optimization standards, making it suitable for corporate websites, international B2B platforms, and technical catalogs.


Product Overview

The 2000A High Voltage Contact Arm is designed for use in VCB (Vacuum Circuit Breaker) applications. It provides:

  • Current rating: 2000A continuous operation

  • Voltage range: Medium and high-voltage switchgear (typically 12kV to 40.5kV systems)

  • Material: Copper alloy with high conductivity and arc-resistant plating

  • Design: Precision-engineered arm to ensure secure engagement with tulip contacts or fixed contact assemblies

  • Performance: Resistant to arc erosion, mechanical wear, and environmental stress


Key Features

  • High Current Capacity: Supports up to 2000A continuous current flow.

  • Arc Resistance: Special surface treatment resists arc erosion during switching.

  • Wear Resistance: Optimized alloy structure ensures long-term durability.

  • Reliable Contact: Maintains low contact resistance for energy efficiency.

  • Compatibility: Designed to fit standard VCB models in medium and high-voltage systems.

  • Safety Compliance: Manufactured according to IEC and GB standards.


Applicable Scope

The 2000A High Voltage Contact Arm for VCB Vacuum Circuit Breaker Resistant to Wear and Arc is widely used in:

1. Power Generation Plants

  • Steam, hydro, and renewable power plants utilize VCBs for generator protection and grid synchronization.

2. Transmission and Distribution Substations

  • Essential for switchgear that ensures safe and efficient distribution of electricity.

3. Industrial Manufacturing Facilities

  • Steel plants, petrochemical industries, mining operations, and cement factories require durable contact arms for high-load machinery.

4. Commercial and Infrastructure Projects

  • Airports, railways, metros, and data centers rely on stable switchgear performance.

5. Renewable Energy Systems

  • Solar farms and wind energy systems integrate VCBs to protect inverters and step-up transformers.


Technical Specifications (Sample Table)

ParameterValue
Rated Current2000A
Applicable Voltage Class12kV – 40.5kV
MaterialHigh-conductivity copper alloy
Surface TreatmentArc-resistant silver or tin plating
Mechanical Durability> 10,000 operations
Operating Environment-25°C to +50°C, up to 95% humidity
Standards ComplianceIEC 62271, GB/T standards

Fault Diagnosis and Repair

Like all electrical components, contact arms may experience performance issues due to operational stress. Below are common faults and solutions:

1. Excessive Heating

  • Cause: High contact resistance due to poor alignment or oxidation.

  • Repair: Clean contact surfaces, check alignment, and ensure proper pressure.

2. Arc Erosion

  • Cause: Frequent switching under load conditions.

  • Repair: Replace heavily eroded contact arms; apply protective coatings if recommended.

3. Mechanical Wear

  • Cause: Long-term mechanical stress and vibration.

  • Repair: Inspect periodically and replace worn arms before failure.

4. Oxidation or Corrosion

  • Cause: Exposure to humid or corrosive environments.

  • Repair: Clean oxidation layer and apply protective grease; consider environmental sealing.

5. Loose Contact

  • Cause: improper installation or deformation under high stress.

  • Repair: Tighten fittings and check spring pressure of the tulip contact.

High Voltage Contact Arm



Maintenance and Care

Proper maintenance and care extend the service life of the contact arm and ensure consistent performance.

Routine Maintenance Checklist

  1. Visual Inspection: Check for arc marks, pitting, or discoloration.

  2. Contact Resistance Measurement: Ensure values remain within standard limits.

  3. Lubrication: Apply conductive grease where specified.

  4. Tightening: Inspect bolts, clamps, and fittings for mechanical looseness.

  5. Environmental Control: Maintain dry and clean switchgear enclosures.

Preventive Maintenance Schedule

IntervalMaintenance Activity
Every 3 monthsVisual inspection and cleaning
Every 6 monthsContact resistance measurement
AnnuallyComprehensive inspection of mechanical and electrical parts
5 yearsOverhaul, replacement of worn components

Customer Feedback

Customers across various industries report high satisfaction with the 2000A High Voltage Contact Arm for VCB Vacuum Circuit Breaker Resistant to Wear and Arc.

  • Power Utilities: “We have used these contact arms in our substations for over 5 years with minimal replacements. Excellent reliability.”

  • Industrial Plants: “The wear resistance is outstanding. Even under heavy switching conditions, contact arms last longer than standard models.”

  • Engineering Contractors: “Easy installation and maintenance reduce downtime during commissioning projects.”

  • Renewable Energy Providers: “Ideal for solar farms where frequent load fluctuations occur. Consistent performance under stress.”


Advantages for End Users

  • Extended Service Life → Reduced replacement frequency and operational costs.

  • Enhanced Safety → Lower risk of overheating and arc-related failures.

  • Efficiency → Low resistance ensures reduced energy losses.

  • Versatility → Applicable in various sectors from utilities to industrial facilities.

  • Compliance → Meets global standards for safety and performance.


Why Choose 2000A High Voltage Contact Arm for VCB?

  • Engineered for long-term reliability.

  • Resistant to wear, arc erosion, and oxidation.

  • Optimized for heavy-duty switchgear applications.

  • Backed by customer trust and positive performance feedback.



The 2000A High Voltage Contact Arm for VCB Vacuum Circuit Breaker Resistant to Wear and Arc is a vital component for high-performance electrical systems. With its superior resistance to wear and arc stress, it ensures uninterrupted operation, reduces maintenance costs, and guarantees safety in power distribution networks.


Its broad applicability, ease of maintenance, and positive customer feedback make it an ideal choice for industries seeking dependable switchgear solutions.


By integrating this advanced contact arm into their VCB systems, operators can ensure long-lasting performance, compliance with international standards, and maximum efficiency in demanding environments.



ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!
Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Copyright ©  2025 Yangmei Electric Group  All rights reserved

Sitemap

This website uses cookies to ensure you get the best experience on our website.

Accept Reject