VCB Tulip Contact for Vacuum Circuit Breaker Electrical Switchgear Parts High Conductivity EB-5-1600A(36 pieces)

    VCB Tulip Contact for Vacuum Circuit Breaker Electrical Switchgear Parts High Conductivity EB-5-1600A(36 pieces)

    The VCB Tulip Contact EB-5-1600A (36 pieces) is designed for vacuum circuit breaker applications, ensuring reliable performance in high voltage switchgear systems.
  • Share:
  • Contact us Inquiry
  • WhatsApp:8613736779975

Dimensional drawing


VCB Tulip Contact for Vacuum Circuit


The VCB tulip contact for vacuum circuit breaker electrical switchgear Parts High Conductivity EB-5-1600A (36 pieces) is engineered to deliver exceptional conductivity, durability, and reliability in high voltage switchgear systems. Designed for modern power distribution networks, this component plays a crucial role in ensuring stable electrical performance under demanding industrial and utility environments.


This page provides a detailed overview of the EB-5-1600A tulip contact, covering design philosophy, installation guidelines, sample schematic diagrams, customer feedback, and after-sales support, while also highlighting its technical advantages.


Key Features at a Glance

FeatureDescription
ModelEB-5-1600A
ApplicationVacuum Circuit Breaker (VCB) Switchgear
Quantity36 pieces per set
MaterialHigh conductivity copper alloy
Primary FunctionEnsures stable current flow between moving and fixed contacts
PerformanceHigh mechanical endurance and electrical stability
InstallationEasy integration with standard VCB switchgear
MaintenanceLow-maintenance with long service life

Design Philosophy of EB-5-1600A Tulip Contact

High Conductivity for Reliable Operation

The EB-5-1600A tulip contact is manufactured using high conductivity copper alloy. This ensures minimal resistance, reduced energy loss, and improved thermal stability during operation. The result is a highly efficient electrical contact ideal for High Voltage switchgear applications.

Precision Engineering

Each tulip contact is crafted with precision tolerance control, ensuring perfect alignment within the vacuum circuit breaker mechanism. This design reduces the risk of contact misalignment and guarantees smooth mechanical motion.

Long-Term Durability

The contact surfaces are treated to resist oxidation, erosion, and mechanical wear. This extends the service life of the tulip contact even under frequent switching operations.

Safety and Reliability

The design integrates arc-resistant geometry, allowing safe current interruption while minimizing the risk of contact failure. Reliability under high short-circuit current conditions is a defining characteristic of the EB-5-1600A.


Technical Specifications

ParameterValue
Rated Current Capacity1600 A
Rated VoltageUp to 12 kV (compatible switchgear)
Contact Resistance≤ 60 μΩ
Mechanical Endurance> 10,000 operations
Material TypeHigh-conductivity copper alloy with surface treatment
Quantity per Set36 pieces
Installation ModeSnap-fit / bolt-tightening with standardized fittings
Operating Temperature−25 °C to +125 °C
Application FieldHigh voltage switchgear, power distribution, substations, industrial plants

Installation Guide

Preparation Before Installation

  1. Check Compatibility – Ensure the EB-5-1600A tulip contact matches the model of your vacuum circuit breaker switchgear.

  2. Inspect Components – Verify all 36 pieces are intact, without physical damage or surface oxidation.

  3. Prepare Tools – Torque wrenches, insulation gloves, and cleaning kits should be available.

VCB Tulip Contact for Vacuum Circuit


Installation Steps

  1. Power Down the System – Switchgear must be de-energized and locked out before installation.

  2. Remove Old Contacts – Carefully disassemble the worn contacts from the breaker.

  3. Clean Mounting Area – Wipe away dust, oxidation, and grease.

  4. Insert New Tulip Contacts – Place EB-5-1600A contacts into the designated slots.

  5. Tighten Connections – Ensure firm and even torque across all fasteners.

  6. Conduct Inspection – Verify contact alignment and mechanical movement.

  7. Test Run – Operate the breaker manually before energizing.


User Feedback and Case Studies

Positive User Experiences

  • Industrial Plant Operator (Asia):
    “After replacing older contacts with the EB-5-1600A, we observed reduced heating and stable performance during peak load conditions. The product’s durability exceeded expectations.”

  • Utility Engineer (Europe):
    “The 36-piece set provided easy installation. Its conductivity and mechanical fit significantly improved breaker operation.”

  • Switchgear Maintenance Team (Middle East):
    “Minimal wear after 8,000 operations. We appreciate the robust design and straightforward replacement process.”

Performance Improvements Reported

Area of ImprovementUser Feedback
ConductivityReduced contact resistance
DurabilityWithstood high operation cycles
SafetyStable performance under fault currents
InstallationSimple integration with existing VCB units

After-Sales Service and Support

Eberry provides comprehensive after-sales service for EB-5-1600A tulip contacts, ensuring customer satisfaction across industries.

Services Offered

  • Technical Guidance: Installation manuals, videos, and step-by-step guides.

  • Training Support: On-site or online training for maintenance teams.

  • Replacement Policy: Defective components covered under warranty.

  • Spare Parts Availability: Continuous stock of EB-5-1600A and related parts.

  • Customer Support: 24/7 service for troubleshooting and consultation.


Benefits of Choosing EB-5-1600A Tulip Contact

  1. Enhanced Electrical Conductivity – Maintains efficient current flow.

  2. Reduced Maintenance Costs – Longer life cycle reduces replacement frequency.

  3. High Compatibility – Fits widely used vacuum circuit breaker switchgear.

  4. Improved Safety – Designed for arc resistance and stable operation.

  5. Global Standards Compliance – Meets IEC and relevant high voltage equipment standards.


Frequently Asked Questions (FAQ)

Q1: How often should tulip contacts be replaced?
A: Replacement intervals depend on operation cycles and load conditions, but EB-5-1600A typically lasts over 10,000 operations before requiring replacement.

Q2: Can EB-5-1600A fit all VCB models?
A: It is compatible with most standard switchgear models rated for 1600 A, 12 kV systems. Verification with technical drawings is recommended.

Q3: What maintenance is required?
A: Regular visual inspection, resistance measurement, and cleaning are sufficient.

Q4: Does installation require specialized tools?
A: Standard torque wrenches and insulation safety gear are adequate.

Q5: Is technical support available for international buyers?
A: Yes, remote and on-site support are available for global clients.


SEO Meta Description (Example for Website)

"Buy VCB Tulip Contact EB-5-1600A (36 pieces) for vacuum circuit breaker switchgear. High conductivity, durable design, easy installation, and reliable after-sales support. Ideal for industrial and utility high voltage electrical systems."



The VCB Tulip Contact for Vacuum Circuit Breaker Electrical Switchgear Parts High Conductivity EB-5-1600A (36 pieces) is an essential component for ensuring reliable, safe, and efficient operation of high voltage switchgear. Its superior conductivity, precision design, and robust durability make it the ideal choice for industrial applications worldwide.

With strong user feedback, detailed installation support, and professional after-sales service, the EB-5-1600A stands as a high-value solution for modern electrical infrastructure.



ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!
Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Copyright ©  2025 Yangmei Electric Group  All rights reserved

Sitemap

This website uses cookies to ensure you get the best experience on our website.

Accept Reject